Choosing PVC Pipe for a Sprinkler or Irrigation System

Choosing PVC Pipe for a Sprinkler or Irrigation System

Underground irrigation is mostly pipe. Choosing the wrong type either wastes money or fails early. This guide explains the labels you will see (Schedule 40, Class 200 and so on) so you can ask for the right thing. Most of the specifics below come from one irrigation tutorial site written by an experienced installer, so treat them as practical guidance, not code. Always check local rules.

Two ways pipe is labeled

  1. Schedule (SCH) 40: a thick-wall pipe whose dimensions follow steel pipe sizes. The source notes that as the pipe size increases, strength and pressure rating decrease.
  2. Class (CL) 160, 200, 315: the class number equals the pressure rating in PSI. Class 200 is rated for 200 PSI.

What the source recommends

Pressure ratings by size (SCH 40)

The same source lists these ratings. Treat them as reference values and confirm against the printed markings on the pipe you buy.

Size Rating (PSI)
1/2" 600
3/4" 480
1" 450
1 1/4" 370
1 1/2" 330
2" 280
2 1/2" 300
3" 260
4" 220

Do not run at the rated pressure

The source gives a rule of thumb: normal operating pressure should not exceed half of the rated pressure, because a valve closing quickly can cause a surge that may double the pressure. Its example is that 1 1/2" pipe should stay at or below 165 PSI. The author says this applies to all PVC pipe, including class-rated pipe. Surge is also known as water hammer, and a licensed irrigation or plumbing professional can advise on how to limit it.

Fittings and joints

Burial depth

The source says codes generally require pressurized mainlines to be buried at least 18 inches deep regardless of pipe type or size. Laterals can be buried at any depth, but the author generally recommends at least 10 inches to reduce breakage. Requirements vary by state and city, and frost depth matters in cold climates. Confirm with your local building or water authority before you dig. Call your local utility locating service before any digging.

Planning checklist

  1. Measure your flow (gallons per minute) and static pressure with a gauge. A flow figure helps you choose pipe size; undersized pipe increases friction loss.
  2. Draw the zones and decide where mainline and laterals will go.
  3. Choose mainline and lateral pipe types as above.
  4. Decide whether you need a backflow preventer. Requirements are set locally; ask your water utility.
  5. Plan drainage or winterization if your area freezes.

Common mistakes

Comparing quotes

Ask each supplier or installer for the pipe type (SCH or class), size, fitting grade, and the working pressure the system is designed for. Compare total installed cost and warranty, not only the price per foot.